Configuring the Adapter for Sybase

Topics:

xx

Configuring the adapter consists of specifying connection and authentication information for each of the connections you want to establish.

Declaring Connection Attributes

How to:

Reference:

In order to connect to the Sybase database server, the adapter requires connection and authentication information. You supply this information using the SET CONNECTION_ATTRIBUTES command. You can:

  • Enter connection and authentication information in the Web Console or the Data Management Console configuration panes. The consoles add the command to the profile you select: the global server profile (edasprof.prf), a user profile (user.prf), or a group profile (if supported on your platform).
  • Manually add the command in the global server profile (edasprof.prf), in a user profile (user.prf), or in a group profile (if supported on your platform).

You can declare connections to more than one Sybase database server by including multiple SET CONNECTION_ATTRIBUTES commands. The actual connection to the Sybase Server takes place when the first query that references the connection is issued. If you issue multiple SET CONNECTION_ATTRIBUTES commands:

  • The connection named in the first SET CONNECTION_ATTRIBUTES command serves as the default connection.
  • If more than one SET CONNECTION_ATTRIBUTES command contains the same connection name, the adapter uses the attributes specified in the last SET CONNECTION_ATTRIBUTES command.

Procedure: How to Configure an Adapter

  1. From the Web Console sidebar, click Connect to Data.

    or

    From the Data Management Console, expand the Adapters folder.

    In the DMC, the Adapters folder opens. In the Web Console, the Adapters page opens showing your configured adapters.

  2. In the Web Console, click the New Datasource button on the menu bar and find the adapter on the page or, in the DMC, expand the Available folder if it is not already expanded.
    On the Web Console, you can select a category of adapter from the drop-down list or use the search option (magnifying glass) to search for specific characters.
  3. In the DMC, expand the appropriate group folder and the specific adapter folder. The group folder is described in the connection attributes reference.
  4. Right-click the adapter name and/or version and select Configure.

    The Add Adapter to Configuration pane opens.

  5. Enter values for the parameters required by the adapter, as described in the chapter for the specific adapter you want to configure.
  6. Click Configure. The configured adapter is added to the Adapters list in the DMC resources tree or the Configured list in the Web Console.
    In the Web Console, the adapter remains on the Available Adapters list with an asterisk to indicate that at least one connection has been configured. You can configure additional connections from either the Configured or Available list by right-clicking the adapter and clicking Add Connection.

Reference: Connection Attributes for Sybase (OCS)

The Sybase adapter is under SQL on the Available drop-down list.

The following list describes the connection attributes for which you can supply values. To complete the attribute declaration, click the Configure button.

Connection name

Logical name used to identify this particular set of connection attributes. The default is CON01.

Server

Name of the Sybase server to access. It must match an entry in the Sybase interfaces file.

Security

There are two methods by which a user can be authenticated when connecting to a database server:

  • Explicit. The user ID and password are explicitly specified for each connection and passed to the database, at connection time, for authentication.
  • Password Passthru. The user ID and password received from the client application are passed to the database, at connection time, for authentication.
User

Primary authorization ID by which you are known to the data source.

Password

Password associated with the primary authorization ID.

Select profile

Select a profile from the drop-down menu to indicate the level of profile in which to store the CONNECTION_ATTRIBUTES command. The global profile, edasprof.prf, is the default.

If you wish to create a new profile, either a user profile (user.prf) or a group profile if available on your platform (using the appropriate naming convention), choose New Profile from the drop-down menu and enter a name in the Profile Name field (the extension is added automatically).

Store the connection attributes in the server profile (edasprof).

Reference: Connection Attributes for Sybase (JDBC)

The Sybase adapter is under SQL on the Available drop-down list.

The following list describes the connection attributes for which you can supply values. To complete the attribute declaration, click the Configure button.

Connection name

Logical name used to identify this particular set of connection attributes. The default is CON01.

URL

Location URL for the JDBC data source.

Security

There are two methods by which a user can be authenticated when connecting to a database server:

  • Explicit. The user ID and password are explicitly specified for each connection and passed to the database, at connection time, for authentication.
  • Password Passthru. The user ID and password received from the client application are passed to the database, at connection time, for authentication.
User

Primary authorization ID by which you are known to the data source.

Password

Password associated with the primary authorization ID.

Driver name

Name of the JDBC driver.

For information, see the driver documentation for the specific release you are using.

IBI_CLASSPATH

Defines the additional Java Class directories or full-path jar names that will be available for Java Services. This value may be set by editing the communications file or in the Web Console. Using the Web Console, you can enter one reference per line in the input field. When the file is saved, the entries are converted to a single string using colon (:) delimiters for all platforms.

Select profile

Select a profile from the drop-down menu to indicate the level of profile in which to store the CONNECTION_ATTRIBUTES command. The global profile, edasprof.prf, is the default.

If you wish to create a new profile, either a user profile (user.prf) or a group profile if available on your platform (using the appropriate naming convention), choose New Profile from the drop-down menu and enter a name in the Profile Name field (the extension is added automatically).

Store the connection attributes in the server profile (edasprof).

Syntax: How to Declare Connection Attributes Manually

Explicit authentication. The user ID and password are explicitly specified for each connection and passed to Sybase, at connection time, for authentication.

ENGINE SQLSYB SET CONNECTION_ATTRIBUTES connection server/userid,password

Password passthru authentication. The user ID and password are explicitly specified for each connection and passed to Sybase, at connection time, for authentication.

ENGINE SQLSYB SET CONNECTION_ATTRIBUTES connection server/

where:

connection

Is the logical name used to identify this particular set of connection attributes.

SQLSYB

Indicates the adapter. You can omit this value if you previously issued the SET SQLENGINE command.

server

Is the name of the Sybase server you wish to access.

userid

Is the primary authorization ID by which you are known to Sybase.

password

Is the password associated with the primary authorization ID.

Example: Declaring Connection Attributes

The following SET CONNECTION_ATTRIBUTES command connects to the Sybase database server named SAMPLESERVER with an explicit user ID (MYUSER) and password (PASS). To ensure security, specify connection attributes from the Web Console, which encrypts the password before adding it to the server profile.

ENGINE SQLSYB SET CONNECTION_ATTRIBUTES CON01 SAMPLESERVER/MYUSER,PASS

The following SET CONNECTION_ATTRIBUTES command connects to the Sybase database server named SAMPLESERVER using Password Passthru authentication:

ENGINE SQLSYB SET CONNECTION_ATTRIBUTES CON01 SAMPLESERVER/

Overriding the Default Connection

How to:

Reference:

Once connections have been defined, the connection named in the first SET CONNECTION_ATTRIBUTES command serves as the default connection. You can override this default using the SET DEFAULT_CONNECTION command.

Syntax: How to Change the Default Connection

ENGINE SQLSYB SET DEFAULT_CONNECTION connection

where:

SQLSYB

Indicates the adapter. You can omit this value if you previously issued the SET SQLENGINE command.

connection

Is the connection defined in a previously issued SET CONNECTION_ATTRIBUTES command. If this name was not previously declared, the following message is issued:

FOC1671, Command out of sequence

Note:

  • If you use the SET DEFAULT_CONNECTION command more than once, the connection name specified in the last command serves as the default connection.
  • The SET DEFAULT_CONNECTION command cannot be issued while an uncommitted transaction (LUW) is pending. In that case, the following message is issued:
    FOC1671, Command out of sequence. 

Example: Selecting the Default Connection

The following SET DEFAULT_CONNECTION command selects the database server named SAMPLE as the default database server:

ENGINE SQLSYB SET DEFAULT_CONNECTION SAMPLE

Reference: Updating the Connection String

The syntax for the CONNECTION_ATTRIBUTES command for this adapter has been enhanced to include a logical connection name that is designed to support the porting of applications from development to production environments. This enhanced syntax may necessitate the migration of existing CONNECTION_ATTRIBUTES commands.

The Web Console Migrate option migrates your server settings to a newer release. To access this option, select Workspace from the menu bar, then select Migrate from the ribbon. This is the recommended approach.

On the Migrate pane, type the full path of the configuration instance directory (EDACONF) and click Continue. Select additional migration options, as shown in the following image, and click Migrate


Server migration

If you choose not to use the Migrate option, please note the following information:

  • Connection names declared prior to Version 7 Release 6.1 are supported.
  • If you create a new connection for the purpose of creating new synonyms, your existing connections are re-saved in a new format, and the existing synonyms continue to work without any changes.
  • If you add a new connection for the purpose of using an existing synonym, you must change the default logical connection name to match the value that is stored in the existing Access File attribute CONNECTION=value.

    For example, suppose that prior to Version 7 Release 6.1, the connection was defined as:

    ENGINE SQLSYB SET CONNECTION_ATTRIBUTES DSN_A/uid,pwd

    When synonyms based on objects stored in this DSN_A are created, the Access Files contains the following description:

    CONNECTION=DSN_A

    If you then add a new connection, you must change the connection name from the default CON01 to DSN_A and save it as DSN_A in order to reuse the existing synonym. The connection is stored in the profile as:

    ENGINE SQLSYB SET CONNECTION_ATTRIBUTES DSN_A DSN_A/uid,pwd 

Controlling the Connection Scope

How to:

The SET AUTODISCONNECT command controls the persistence of connections when using the adapter for each of the connections you want to establish.

Syntax: How to Control the Connection Scope

ENGINE SQLSYB SET AUTODISCONNECT ON {FIN|COMMAND|COMMIT}

where:

SQLSYB

Indicates the adapter. You can omit this value if you previously issued the SET SQLENGINE command.

FIN

Disconnects automatically only after the session has been terminated. FIN is the default value.

COMMAND

Disconnects automatically after each request. Depending on how often the event occurs, the SET AUTODISCONNECT command may result in considerable overhead. Almost all of this overhead is not related to the server. It is related to the operating system and the data source.

COMMIT

Disconnects automatically only after COMMIT or ROLLBACK is issued as a native SQL command.

WebFOCUS

Feedback