The following are known issues that apply to WebFOCUS
Autoprompt:
- The Responsive Autoprompt image to indicate that a group of filter fields are chained does not display. The chaining symbol
displays at run time for each set of parameters for fields in a single path dimension hierarchy.
- Save Parameter reports created from the Autoprompt page do not inherit the properties of the report from which they were created.
The Only Run as Deferred Report property is the only property that Save Parameter reports inherit from the original.
- A request issued from the Responsive Autoprompt page generates an unknown fieldname error and fails to run if one of the parameter-based
fieldnames in the request includes FOC_NONE in the list of values assigned to it. This problem does not occur when using the
HTML Autoprompt page.
- A Responsive Autoprompt chained filter does not limit the values available for selection based on the selections for the prior
filter when the fields referenced in the chained filter are not listed in the order specified in the data definition .mas
file.
- Responsive Autoprompt chained fields with a descending sort order (SORT=DESCENDING) do not list values in descending sort
order when using a Google Chrome™ or Mozilla Firebox® browser. These values are listed correctly when using the Internet Explorer
11® or Microsoft Edge® browser.
- Responsive Autoprompt dynamic chained filters that specify a field as a display value do not list field values due to an
Autoprompt processing error.